SuPerMax 3100 Capabilities
1. Assay for absorbance, fluorescence and luminescence, and having a variety of fittingcurves for analysis.
2. Assay for activity of protease, kinase and phospholipase.
3. Protein quantification, supporting the methods of UV, NanoOrange, Bradford, Lowry.
4. DNA/RNA quantification, supporting the methods of PicoGreen, RiboGreen.
5. Assay for luciferase.
6. Assay for luminescence of ALP (alkaline phosphatase) with its substrates.
7. Assay for reactive oxygen species, ATP, cAMP.
8. Assay for cellular activity and cytotoxicity.
9. Assay for absorbance of endotoxin-TAL (Tachypleus Amebocyte Lysate) and microbial
suspension.
10. Assay for spectral scanning.
11. The excitation and emission components are high resolution gratingmonochromators that can set the optimal excitation and emission wavelengths.
12. The built-in grating monochromator has a wavelength range of 190 ~ 1000 nm, wideapplication.
13. The wavelength resolution of 1 nm, wavelength repeatability of up to 0.2 nm.
14. Top and bottom optics for fluorescence assay.
15. Kinetic measurements, assay for enzymology and flash luminescence.
16. Spectral scanning mode,accurate excitation and emission spectra.
17. Wide temperature range incubation, the maximum temperature 65℃.
18. Oscillation module, no need another shaker.
19. Xenon lamp for light source, High luminous intensity and stability.
20. Optional dispensers for fast assays.
21. Sample detector and reference detector ensure precise detection.
22. Microplate analysis workstation with powerful data analysis capabilities.
23. Automation with parameter setting and self-testing.
24. Using USB interface for easy instrument control and data transfer. 25. Performance is similar with the products from developed countries, cost-effective
SuPerMax 3100 Performance values
1. General Feature
Light source: Xenon flash lamp
Temperature: (RT + 2℃) ~ 65℃
Shaking mode: Linear, cross, orbital
Shaking speed: High, middle, slow
Plate: 96, 384 well (other plate can be customized)
2. Absorbance
Detector: Photocell
Spectral range: 190 nm ~ 1000 nm
Wavelength accuracy: ±1.0 nm
Wavelength reproducibility: <0.2 nm
OD linear range: 0 ~ 4 Abs (96well, 450 nm), ±2%
Inter-hole reproducibility: < 0.006
Cuvettes: None
3. Fluorescence
Detector: PMT
Excitation spectral range: 190 nm~1000 nm
Emission spectral range: 270 nm~850 nm
Wavelength resolution: 1 nm
Bandwidth: 10 nm or 20 nm
Wavelength accuracy: <0.2 nm
Fluorescence intensity:
Top: < 0.5 fmol (FITC/well; 384 well)
Bottom: < 5 fmol (FITC/well; 384 well)
Magnitude detection:
Top: > 6 decades
Bottom: > 5.5 decades
Read mode: Top or Bottom
Cuvettes: None
4. Luminescence
Detector: Photon counting PMT
Spectral range: 300 nm ~ 650 nm, scanning mode: 270 nm ~ 850 nm Limit of detection: 7 amol ATP/well
Dynamic range > 7 decades
Inter-hole interference: < 0.2% (white plate)
Dispensers: Optional
5. Dispensers (Optional)
Number: 1 or 2
Volume: 10-1000uL
SuPerMax 3100 Main Construct:
1. Main engine (include: light source, detector, incubator, shaker)
2. Workstation software of SuPerMax 3100 Multi-Mode Microplate Reader
Instrument Accessories (Optional)
1. MF-10 incubating oscillator
2. Dispensers
3. Audit trail